Stock Number 002522/DCAL - Revised Nov. 2009
OPERATING MANUAL
Delta Controls Limited
Island Farm Avenue, West Molesey, Surrey KT8 2UZ, UK
T +44 (0) 20 8939 3500 F +44 (0) 20 8783 1163 E sales@delta-controls.com W www.delta-controls.com
How can we help you?
Technical Datasheets and IOM Instructions for all Delta Controls'
pressure and temperature measurement products are available
from our website at www.delta-controls.com.
For Service and Repair enquiries, please contact the Sales
Engineering Teams on +44 (0)20 8939 3500 or email
D-CAL
CONFIGURATOR
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1 - CONFIGURATOR

Stock Number 002522/DCAL - Revised Nov. 2009OPERATING MANUALDelta Controls LimitedIsland Farm Avenue, West Molesey, Surrey KT8 2UZ, UKT +44 (0) 20 8

Pagina 2 - DISCLAIMER

Configuration using the Local DisplayView This menu option is an unprotected level, most of the internal parameters canbe viewed using this

Pagina 3 - CONTENTS

{ACCESS 1}21{SELFTEST}[SELECT]If you suspect the functionality of the transmitter, SELFTEST when passed will give a very highconfidence level of the

Pagina 4 - {ACCESS 2}

The access restrictions apply to local configuration only. It is assumed that remote access, viaa portable HART® configurator on a host computer, is a

Pagina 5

(Nb There is no Page 18){ACCESS 1}19{OUTPUT}[SELECT]The transmitter’s analogue output and percentage display may be linear or square root, selectedby

Pagina 6

{VIEW}The view menu is not protected by a password, as no changes can be made from within this menuoption. After five minutes it will return to the mo

Pagina 7

{ACCESS 1}Pressing {CHANGE} wil move down through the menu.At the end of each sub-menu, select {ESCAPE} to return to the higher menu.(Nb There is no

Pagina 8

{ACCESS 1}15{INPUT} [SELECT]{PV UNITS}[SELECT]Because the measured pressure is converted to a digital number the way the numberis displayed can be sc

Pagina 9

WARRANTYWe guarantee this instrument against faulty workmanship and material for a period of one year fromthe date of delivery. The company undertakes

Pagina 10

Commissioning and Set-up ExamplesHow to change the engineering units.Objective:- Change the engineering units from the default, pascals, to Bar.From M

Pagina 11

DOCUMENT CONVENTIONSThis manual uses the following typographical conventions to describe the functionality of thetransmitter. The blind in

Pagina 12 - ACCESS 2

{ACCESS 2}READ THIS SECTION BEFORE ENABLING THE PASSWORD{PASSWORD}[SELECT]The password function controls access to the menu levels of the transmitter.

Pagina 13 - ACCESS 1

LOCAL DISPLAYPERFORMANCE SPECIFICATION :-The local display / configurator is not connected via the signal loop, but accesses the micropr

Pagina 14

{ACCESS 2}25The FIXLOOP and trim functions are used to remove any differences between calibrationand site current standards. The electronics generate

Pagina 15

Commands and HART Numbers used by 2HT(Only user-accessible commands are listed)Number Class Local Description0 U V Read Unique Identif

Pagina 16

{ACCESS 2}The (TRIMxxx) functions are used to trim the Lower and Upper Range Values of the analogue todigital converter (ADC) to an accurately generat